Nozzle Control Governing is used in large power steam turbines to which very high pressure steam is supplied. In this method, the total number of nozzles of a turbine is grouped in a number of groups varying from two to twelve groups and each group of nozzle is supplied steam controlled by valves. the valves are poppet valves and are opened or closed by automatic devices. Number of groups of nozzle in operation at a particular instant depends upon the land on the steam turbine.
The nozzles are divided in four groups N1 , N2 , N3 , N4 and are controlled by valves V1, V2, V3, V4 respectively. At full load on the turbine, steam flows through nozzles of all groups . At part load, only the required number of groups of nozzles is operated. The arc of admission is limited to 180* or less.
The Nozzle control governing is restricted to the first stage of the turbine, the nozzle area in other stages remaining constant . It is suitable for simple impulse turbine.